  • Operating range, white 90%0.005 ... 0.2 m
  • Operating range, gray 18%0.01 ... 0.16 m
  • Operating range, black 6%0.015 ... 0.13 m
  • Operating range limit0.005 ... 0.2 m
  • Adjustment range15 ... 200 mm
  • Light sourceLED, Infrared
  • Electrical data
  • Protective circuitShort circuit protected, Polarity reversal protection
  • Performance data
  • Supply voltage UB10 ... 30 V, DC, Incl. residual ripple
  • Residual ripple0 ... 15 %, From UB
  • Open-circuit current0 ... 15 mA
  • Outputs
  • Number of digital switching outputs2 Piece(s)
  • Switching output 1
  • Switching elementTransistor, PNP
  • Switching principleLight switching
  • Switching output 2
  • Switching elementTransistor, PNP
  • Switching principleDark switching

Các model sản phẩm:

 

Bitzer CDU - Air Cooled (LH) - Ecoline LH265/4GE-20Y
(With Pressure Transmitters for application limit monitoring)
BÜRKERT Code: 00002158
Description: 2/2-way piston control Angle-Seat Valve
Type: 2000

BÜRKERT

Code: 00001398
Description: 2/2-way-piston-operated angle-seat valve
2000-A-2-65,0-EE-RG-GM90-B-F*MC13
Type 2000
Control function A - closed by spring force
Paths/positions 2 - 2 ways / 2 position
Orifice size 65,0 - 65mm (2 1/2")
Seal material EE - PTFE
Body material RG - gunmetal
Port connection GM90 - G2 1/2 threaded port
Actuator version B - PA-actuator, MS-threaded
bushing at connection of pilot air
Actuator size F - Dm 80mm
Special Feature:
MC13 - flow above seat
Pressure min 0 bar
Pressure max 14 bar
Pilot pres. min 1,60 bar
Pilot pres. max 10 bar
KV 77 m3/h
T medium min -10 °C
T medium max 180 °C
T ambient min -10 °C
T ambient max 60 °C

BÜRKERT

Code: 00169391
Description: 2/2-way-piston-operated valve
2012-A2-80,0-EE-VA-SA49-C-H-N8-0000*MC13+MC16+NK51
Type 2012
Control function A - closed by spring force
Paths/positions 2 - 2 ways / 2 position
Orifice size 80,0 - 80mm (3")
Seal material EE - PTFE
Body material VA - stainless steel
Port connection SA49 - Weld end 88,9 x 2,3
according to ISO 4200, DIN EN ISO 1127, DIN 11866 series B
Actuator version C - PA-actuator, VA-threaded bushing at connection of pilot air
Actuator size H - Dm 125mm
Interface N8 - nipple thread M100 x 2 (standard DN 80)
connection of pilot air 0000 - standard pilot air connection resp. integral construction
Special Feature:
MC13 - flow above seat
MC16 - O-ring between cover and actuator housing
NK51 - packed seal enclosed
Pressure min 0 bar
Pressure max 10 bar
Pilot pres. min 2 bar
Pilot pres. max 7 bar
KV 110 m3/h
T medium min -10 °C
T medium max 180 °C
T ambient min -10 °C
T ambient max 60 °C
E+E Code: EE23-T4HS3K5D1/GA6SBL-20SBH120DT2
Humidity/Temperature Sensor

E+H

Code: 8F3B50 - AAIBAEAFAASAD2SAA1
Description: Coriolis flowmeter
E2S Model: BExL25DFR008AS2A1R
Explosion Proof PA Loudspeakers 25W
E2S Model: BExL25DFV100AS2A1R
Explosion Proof PA Loudspeakers 25W

Eurotherm

Part no : 3208/VC/VH/RRRX/R/4XL/S/ENG/ENG/XXXXX/XXX
MODEL (3208) Controller
UNIT TYPE (VC) Motorised Valve Controller
SUPPLY VOLTAGE (VH) 85 - 264 Vac
OUTPUT OPTIONS 1 2 3 (RRRX) relay/relay/relay
AA RELAY OP4 (R) Relay
OPTION BOARD 4XL - 2 Wire RS485 Comms + Logic Input
FASCIA COLOUR (S) Silver
PRODUCT LANGUAGE (ENG) English
MANUAL LANGUAGE (ENG) English
Note: TKS932133000 is obsoleted
Eurotherm Part no : ITOOLS/NONE/USB/////XXXXX
Cable and SW for the configuration from PC
Greisinger (GHM) Code: GMH 3695
Air oxygen measuring device, with datalogger
Range: 0.0 ... 100.0 % O₂ Vol
Temp Range: -5 ... +50 °C
Air Pressure Range: 300 ... 5000 hPa abs, pressure port for tube 6/4; Sensor con': 6-pin screened Mini-DIN-Socket
Datalogger: autom. 8000 data sets, manually 1000 data sets
Output: Serial interface, analog output 0 ... 1 V scalable
Greisinger (GHM) Code: GGA370-L04
Atmospheric oxygen sensor, open sensor type
O₂ sensor element: GOEL 370, protection gases with higher CO₂ concentrations and O₂ below < 35 vol. % O₂
Measuring range oxygen concentration: 0 ... 100 % Vol. O₂, recommended 0.2 ... 35 % vol. O₂ (beyond reduced precision)
Cable length: 4m